BH-485-ORP Kikohoʻe ORP Sensor

ʻO ka wehewehe pōkole:

★ Ana i ka laulā: -2000mv~+2000mv
★ Kūkākūkā: Modbus RTU RS485
★ Nā hiʻohiʻona: pane wikiwiki, ikaika anti-interference hiki
★ Ke noi: wai ʻino, wai kahawai, wai ʻauʻau


  • facebook
  • linkedin
  • sns02
  • sns04

Huahana Huahana

ʻIkepili ʻenehana

He aha ka ORP?

Manual

BH-485 Series of online ORP electrode, hoʻohana i ke ʻano ana electrode, a ʻike i ka uku pānaʻi maʻamau i loko o nā electrodes, ʻike ʻokoʻa o ka hopena maʻamau.Electrode i lawe mai i ka electrode composite, precision kiʻekiʻe, kūpaʻa maikaʻi, ke ola lōʻihi, me ka pane wikiwiki, ke kumukūʻai haʻahaʻa haʻahaʻa, nā ʻano ana o ka pūnaewele manawa maoli a me nā mea ʻē aʻe. Hiki i ke ala uea ke komo maʻalahi i nā pūnaewele sensor.


  • Mua:
  • Aʻe:

  • Hoʻohālike BH-485-ORP
    Ana ʻana ORP, Mahana
    Anana laula mV: -1999~+1999 Mahana: (0~50.0) ℃
    Ka pololei mV: ±1 mV Mahana: ±0.5 ℃
    Olelo Hooholo mV: 1 mV Mahana: 0.1 ℃
    Lako ikehu 24V DC
    Ka hoopau mana 1W
    ʻano kamaʻilio RS485(Modbus RTU)
    Ka lōʻihi o ke kaula 5 mika, hiki iā ODM ke hilinaʻi i nā koi o ka mea hoʻohana
    Hoʻokomo ʻO ke ʻano hoʻopololei, pipeline, circulation type etc.
    Nui nui 230mm×30mm
    Mea hale ABS

    ʻIke ʻia ka hiki ke hoʻemi ʻana o ka Oxidation Reduction Potential (ORP a i ʻole Redox Potential) i kahi ʻōnaehana wai e hoʻokuʻu a ʻae paha i nā electrons mai nā hopena kemika.Ke makemake ka ʻōnaehana e ʻae i nā electrons, he ʻōnaehana oxidizing ia.Ke hoʻokuʻu ʻo ia i nā electrons, he ʻōnaehana hōʻemi.Hiki ke loli ke ʻano hoʻemi o ka ʻōnaehana ma ka hoʻokomo ʻana i kahi ʻano hou a i ʻole ke loli ka manaʻo o kekahi ʻano i kēia manawa.

    Hoʻohana ʻia nā waiwai ORP e like me nā waiwai pH e hoʻoholo ai i ka maikaʻi o ka wai.E like me ka hōʻike ʻana o nā waiwai pH i ke kūlana pili o kahi ʻōnaehana no ka loaʻa ʻana a i ʻole ka hāʻawi ʻana i nā ion hydrogen, ʻike ʻia nā waiwai ORP i ke kūlana pili o kahi ʻōnaehana no ka loaʻa ʻana a i ʻole ka nalowale ʻana o nā electrons.Hoʻopili ʻia nā waiwai ORP e nā mea hoʻokahe a me nā mea hoʻohaʻahaʻa a pau, ʻaʻole wale nā ​​​​ʻakika a me nā kumu e hoʻoikaika i ke ana pH.

    Mai kahi hiʻohiʻona mālama wai, hoʻohana pinepine ʻia nā ana ORP e kāohi i ka disinfection me ka chlorine a i ʻole ka chlorine dioxide i loko o nā hale hoʻomaha, nā loko ʻauʻau, nā lako wai inu, a me nā noi mālama wai ʻē aʻe.No ka laʻana, ua hōʻike nā haʻawina e hilinaʻi nui ana ke ola o ka bacteria i ka wai i ka waiwai ORP.I loko o ka wai ʻōpala, hoʻohana pinepine ʻia ke ana ORP e kāohi i nā kaʻina hana lapaʻau e hoʻohana ana i nā hopena lapaʻau olaola no ka wehe ʻana i nā mea haumia.