Mea ʻike conductivity inductive kikohoʻe (Kūpono no ka mahana maʻamau)

Wehewehe Pōkole:

★ Kumu Hoʻohālike: IEC-DNFA

Mea Pūpū: PFA

★ Mahana Hana: -20℃ ~ 80℃

★ Ka laulā o ke ana: 0.5mS/cm -2000mS/cm;

★ Pololei:±2% a i ʻole±1 mS/cm (E lawe i ka mea nui aʻe);±0.5℃

★ Palapala Hoʻokele: Modbus RTU


  • Facebook
  • sns02
  • sns04

Nā kikoʻī huahana

https://www.boquinstruments.com/acid-alkaline-concentration-sensor/

He kuleana koʻikoʻi ko nā mea ʻike conductivity i ke ana ʻana i ka conductivity uila o ka wai i ka manawa maoli, e hāʻawi ana i nā ʻike waiwai i kona maʻemaʻe, ka paʻakai a me ka maikaʻi holoʻokoʻa. Hoʻohana nā mea ʻike conductivity toroidal, i ʻike ʻia hoʻi he mau mea ʻike conductivity inductive, i nā ana conductivity toroidal i nā noi i maʻalahi i nā pilikia e like me ka fouling kiʻekiʻe a i ʻole ka uhi ʻana, ka pala metala, ka conductivity kiʻekiʻe, a me ka pakeneka o ka hoʻohuihui. Loaʻa i nā mea ʻike nā wili electrode e noho pale ʻia mai ka hoʻopili pololei ʻana me ke kaʻina hana, e hōʻoiaʻiʻo ana i ka hilinaʻi. Hoʻopaʻa ʻia i loko o nā mea e like me PEEK/PFA, ua pale ʻia kēia mau wili i kūlike ʻia mai nā hopena kaʻina hana maikaʻi ʻole, e hāʻawi ana iā lākou i kūpono no nā ʻano noi like ʻole.

ʻO kēia huahana kahi mea ʻike conductivity inductive kikohoʻe hou loa i hoʻomohala kūʻokoʻa ʻia a hana ʻia e kā mākou hui. He māmā ka mea ʻike, maʻalahi ke hoʻouka, me ke ana pololei kiʻekiʻe, ka pane koʻikoʻi, ke kūpaʻa ikaika i ka pala a hiki ke hana paʻa no ka manawa lōʻihi. Ua lako ʻia me kahi probe mahana i kūkulu ʻia no ka uku mahana manawa maoli. Hiki ke hoʻonohonoho mamao ʻia a hoʻoponopono ʻia, a maʻalahi hoʻi e hana. Hiki ke hoʻohana ʻia me ka mika SJG-2083CS, a hiki ke hoʻokomo ʻia ma ke ʻano i lalo o ka wai a i ʻole ka pipeline e ana i ka waiwai pH o ka wai i ka manawa maoli. Loaʻa iā ia kahi ākea o nā noi.

Luna Hoʻokele Hana

Hoʻokomo nā mea ʻike conductivity inductive i kahi au haʻahaʻa i loko o kahi loop pani o ka hopena, a laila e ana i ka nui o kēia au e hoʻoholo ai i ka conductivity o ka hopena. Hoʻokele ka mea kālailai conductivity iā Toroid A, e hoʻoulu ana i kahi au alternating i loko o ka hopena. Ke kahe nei kēia hōʻailona au
i loko o kahi loop pani ma o ka sensor bore a me ka hopena e hoʻopuni ana. ʻIke ʻo Toroid B i ka nui o ke au i hoʻokomo ʻia e kūlike ana i ka conductance o ka hopena. Hana ka mea kālailai i kēia hōʻailona a hōʻike i ka heluhelu like.

Nā Palena ʻenehana

Inoa Huahana Mea ʻike conductivity inductive kikohoʻe (Kūpono no ka mahana maʻamau)
Hoʻohālike IEC-DNFA
Mea Pūpū PFA
Mahana Hana -20℃ ~ 80℃
Kaomi Hana Max 16bar (1.6MPa)
Papa Pale Wai IP65
Pae Ana 0.5mS/cm -2000mS/cm;Ua like ka pae mahana me ka mahana o ke kaʻina hana
Pololei ±2% a i ʻole ±1 mS/cm (E lawe i ka mea nui aʻe); ±0.5 ℃
Hoʻoholo 0.01mS/cm;0.01℃
Lako ikehu 12 V DC-30V DC; 0.02A; 0.6W
Kamaʻilio ʻO Modbus RTU
Ana 215*32.5mm

 

 

https://www.boquinstruments.com/digital-inductive-conductivity-sensor-suitable-for-normal-temperature-product/
https://www.boquinstruments.com/digital-inductive-conductivity-sensor-suitable-for-normal-temperature-product/
https://www.boquinstruments.com/digital-inductive-conductivity-sensor-suitable-for-normal-temperature-product/

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou