Koena Klorine Analyzer
-
DPD Colorimetry Chlorine Analyzer CLG-6059DPD
DPD Colorimetry Chlorine Analyzer CLG-6059DPDʻO kēia huahana he DPD koena chlorine online analyzer i hoʻomohala kūʻokoʻa a hana ʻia e kā mākouhui. Hiki i kēia mea hana ke kamaʻilio me PLC a me nā mea hana ʻē aʻe ma o RS485 (Modbus RTUprotocol), a loaʻa iā ia nā ʻano o ka kamaʻilio wikiwiki a me ka ʻikepili pololei.Palapala noiHiki i kēia mea loiloi ke ʻike maʻalahi i ke koena o ka chlorine i loko o ka wai ma ka pūnaewele. ʻO ka hilinaʻiHoʻohana ʻia ke ʻano colorimetric DPD maʻamau, a hoʻohui ʻia ka reagent noana colorimetric, i kupono no ka nana ana i ke koena o ka chlorine i loko o kake kaʻina hana o ka chlorination a me ka disinfection a ma ka pūnaewele paipu wai inu.Nā hiʻohiʻona:1) Hoʻokomo mana ākea, hoʻolālā pale pā.2) DPD colorimetric ala, ʻoi aku ka pololei a paʻa ke ana.3) Ana 'akomi a me ka calibration 'akomi.4) He 180 kekona ka manawa ana.5) Hiki ke koho ʻia ka manawa ana: 120s~86400s.6) Hiki iā ʻoe ke koho ma waena o ke ʻano maʻamau a manual paha.7) 4-20mA a me RS485 puka.8) Hana mālama ʻikepili, kākoʻo U disk export, hiki ke nānā i ka ʻikepili mōʻaukala a me ka calibration.Inoa Huahana ʻIkepili Klorine Online Ana kumu DPD colorimetry Hoʻohālike CLG-6059DPD Laulā Ana 0-5.00mg/L(ppm) pololei E koho i ka nui o ± 5% ana ana a i ʻole ±0.03 mg/L(ppm) Olelo Hooholo 0.01mg/L(ppm) Lako ikehu 100-240VAC, 50/60Hz Hoʻopuka Analog 4-20mA pukana ,Max.500Ω Nā kamaʻilio RS485 Modbus RTU Hoʻopuka Alarm 2 relay ON/OFF contacts, hoʻonohonoho kūʻokoʻa o nā helu alarm Hi/Lo, me ka hoʻonohonoho hysteresis, 5A/250VAC a i ʻole 5A/30VDC Waihona ʻIkepili Hana mālama ʻikepili, kākoʻo i ka hoʻokuʻu disk U Hōʻike 4.3inihi waihoʻoluʻu LCD hoʻopā pale hōʻike Ana / Kaumaha 500mm * 400mm * 200mm (Loihi * laula * kiʻekiʻe); 6.5KG (ʻAʻohe reagents) Reagent 1000mLx2, ma kahi o 1.1kg ka nui; hiki ke hoʻohana ma kahi o 5000 mau manawa Ana I waena 120s~86400s; 600s paʻamau manawa ana hookahi Ma kahi o 180s ʻŌlelo Pākē/English Nā Kūlana Hana Ka wela: 5-40 ℃
Humidity: ≤95%RH (ʻaʻole condensing)
Hoʻohaumia: 2
Kiʻekiʻe: ≤2000m
Overvoltage: II
Kahe kahe: 1L/min ua paipaiKūlana hana Laʻana kahe kahe: 250-300mL/min, Laʻana inlet kaomi: 1bar(≤1.2bar)
Laʻana wela: 5 ~ 40 ℃ -
Analyzer Klorine Koe Online
★ No Hoʻohālike: CL-2059B
★ Hua'ōlelo: 4-20mA
★ Kūkākūkā: Modbus RTU RS485
★ Ana Ana: Ke koena Chlorine/Chlorine Dioxide, Mahana
★ Mana Mana: AC220V
★ Nā hiʻohiʻona: maʻalahi e hoʻouka, pololei kiʻekiʻe a liʻiliʻi i ka nui.
★ Hoʻohana: Ka wai inu a me nā mea kanu wai etc
-
Hoʻohana ʻia ka mea analyzer chlorine koena pūnaewele no ka wai ʻōpala lāʻau
★ No Ke Ana Hoʻohālike: FLG-2058
★ Hua'ōlelo: 4-20mA
★ Kūkākūkā: Modbus RTU RS485
★ Ana Ana: Ke koena Chlorine/Chlorine Dioxide, Mahana
★ Mana Mana: AC220V
★ Nā hiʻohiʻona: maʻalahi e hoʻouka, pololei kiʻekiʻe a liʻiliʻi i ka nui.
★ Hoʻohana: ʻO ka wai ʻino lāʻau lapaʻau, ka wai ʻino ʻoihana etc
-
Hoʻohana ʻia ka Analyzer Chlorine Koe Online no ka wai inu
★ Ka helu kumu: CLG-6059T
★ Kūkākūkā: Modbus RTU RS485
★ Ana Ana: Ke koena Chlorine, pH a me ka Mahana
★ Mana Mana: AC220V
★ Nā hiʻohiʻona: 10-inch kala hoʻopā pale hōʻike, maʻalahi e hana;
★ Hoʻolako ʻia me nā electrodes kikohoʻe, plug a hoʻohana, hoʻonohonoho maʻalahi a mālama;
★ Hoʻohana: Ka wai inu a me nā mea kanu wai etc
-
Mea Analyer Koena Chlorine Online
★ No Ke Ana Hoʻohālike: CL-2059S&P
★ Hua'ōlelo: 4-20mA
★ Kūkākūkā: Modbus RTU RS485
★ Hāʻawi mana: AC220V a i ʻole DC24V
★ Nā hiʻohiʻona: 1. Hiki i ka ʻōnaehana hoʻohui ke ana i ke koena chlorine a me ka mahana;
2. Me ka mana kumu, hiki iā ia ke hoʻopuka i nā hōʻailona RS485 a me 4-20mA;
3. Hoʻolako ʻia me nā electrodes kikohoʻe, plug a hoʻohana, hoʻonohonoho maʻalahi a mālama;
★ Hoʻohana: ʻO ka wai ʻōpala, wai kahawai, wai ʻauʻau
-
Mea Analyer Koena Chlorine Online
★ No Hoʻohālike: CL-2059A
★ Hua'ōlelo: 4-20mA
★ Kūkākūkā: Modbus RTU RS485
★ Hāʻawi mana: AC220V a i ʻole DC24V
★ Nā hiʻohiʻona: pane wikiwiki, ikaika anti-interference hiki
★ Hoʻohana: ʻO ka wai ʻōpala, wai kahawai, wai ʻauʻau